SAMWONTECH
3rd Edition of TEMI880 IM : Aug. 22. 2005 Page 63 / 123
Inner Signal Action
Setting Inner Signal Action
INPUT = 0.0 ~ 100.0
EUS 0.5% = 0.5
OPER. MODE = PROG
ITEM = HUMI
TYPE = PV
RANGE LOW = 30.0%
RANGE HIGH = 50.0%
DIRECT = IN BAND
DELAY TIME = 00.00
INPUT = 0.0 ~ 100.0
EUS 0.5% = 0.5
OPER. MODE = PROG
ITEM = HUMI
TYPE = PV
RANGE LOW = 30.0%
RANGE HIGH = 50.0%
DIRECT = OUT BAND
DELAY TIME = 00.00
INPUT = 0.0 ~ 100.0
OPER. MODE = PROG
ITEM = HUMI
TYPE = SP
RANGE LOW = 30.0%
RANGE HIGH = 50.0%
DIRECT = IN BAND
DELAY TIME = 00.10
INPUT = 0.0 ~ 100.0
OPER. MODE = PROG
ITEM = HUMI
TYPE = TSP
RANGE LOW = 30.0%
RANGE HIGH = 50.0%
DIRECT = OUT BAND
DELAY TIME = 00.00
Inner Signal Action
50.0
SEG1 SEG2 SEG3 SEG4 SEG5
30.0
ON
OFF
IS
HYS
50.5
HYS
29.5
PV
INB
HYS
49.5
HYS
30.5
50.0
SEG1 SEG2 SEG3 SEG4 SEG5
30.0
ON
OFF
IS
PV
OUTB
OUTB
50.0
SEG1 SEG2 SEG3 SEG4 SEG5
30.0
ON
OFF
IS
SP
INB
DELAY TIME
50.0
SEG1 SEG2 SEG3 SEG4 SEG5
30.0
ON
OFF
IS
SP
OUTB
OUTB